ML_FF_NMDINT = [integer]
Default: ML_FF_NMDINT = 10 

Description: Tag to control the minimum interval to get training samples in the machine learning force field method.


This tag defines a lower threshold for taking new configurations from the MD, so that as long as the upper threshold for the Bayesian error (e.g. ML_FF_CDOUB times ML_FF_CTIFOR) is not exceeded, at least ML_FF_NMDINT MD steps are preformed using the MLFF (i.e. no first principles calculation is performed). This is the default method, and avoids that many nearly identical structures are added.

Related Tags and Sections

ML_FF_LMLFF, ML_FF_ISAMPLE