EINT = [real1] [real2] | [real1]
Default: EINT = not set
Description: EINT sets the energy interval for bands contributing to the calculation of the partial charge density in eV.
- EINT= [real1] [real2]:
- If two values are given, the energy interval between those values is used.
- EINT= [real1]:
- If only one value is given, the Fermi energy is used as the other limit [real2] of the interval.
Important: The energies passed in EINT are used as set if NBMOD = -2, but will be added to the Fermi energy ( + real1 and + real2) if NBMOD = -3. |
If [real1] is larger than [real2], the two values will be flipped internally, so a meaningful energy interval is used.
If EINT is set, but NBMOD is not, it will be internally set to NBMOD = -2, and the input values of EINT will be treated as absolute energies.
EINT can be conveniently used in combination with NBMOD = -3 to mimic the bias-voltage for simulating a scanning tunneling microscope image.