The standard Nose Hoover suffers from well known issues, such as the ergodicity violation in the case of simple harmonic oscillator. As proposed by Martyna and Klein<ref>J. Martyna, M. L. Klein, and M. Tuckerman, ''J. Chem. Phys.'' 97, 2635 (1992).[https://pubs.aip.org/aip/jcp/article/97/4/2635/927962/Nose-Hoover-chains-The-canonical-ensemble-via]</ref>, these problems can be solved by using multiple Nose Hoover thermostats connected in a chain. Although the underlining dynamics is non-Hamiltonian, the corresponding equations of motion conserve the following energy term:  
The standard Nose Hoover suffers from well known issues, such as the ergodicity violation in the case of simple harmonic oscillator. As proposed by Martyna and Klein<ref>[https://pubs.aip.org/aip/jcp/article/97/4/2635/927962/Nose-Hoover-chains-The-canonical-ensemble-via J. Martyna, M. L. Klein, and M. Tuckerman, ''J. Chem. Phys.'' 97, 2635 (1992)]</ref>, these problems can be solved by using multiple Nose Hoover thermostats connected in a chain. Although the underlining dynamics is non-Hamiltonian, the corresponding equations of motion conserve the following energy term:  


::<math>
::<math>

Revision as of 07:22, 22 April 2023

The standard Nose Hoover suffers from well known issues, such as the ergodicity violation in the case of simple harmonic oscillator. As proposed by Martyna and Klein[1], these problems can be solved by using multiple Nose Hoover thermostats connected in a chain. Although the underlining dynamics is non-Hamiltonian, the corresponding equations of motion conserve the following energy term:

where is the Hamiltonian of the physical system, and are the numbers of thermostats and atoms in the cell, respectively, and , , and are the position, momentum, and mass-like parameter associated with the thermostat . Just like the total energy in NVE ensemble, is valuable for diagnostics purposes. Indeed, a significant drift in indicate that the corresponding computational setting is suboptimal. Typical reasons for this behavior involve noisy forces (e.g., because of a poor SCF convergence) and/or a too large integration step (defined via POTIM).

The number of thermostats is controlled by the flag NHC_NCHAINS. Typically, this flag is set to a value between 1 and 5, the maximal allowed value is 20. In the special case of NHC_NCHAINS=0, the thermostat is switched off, leading to a MD in microcanonical ensemble. Another special case of NHC_NCHAINS=1 corresponds to the standard Nose-Hoover thermostat.

The only thermostat parameter is NHC_PERIOD, corresponding to a characteristic time scale () of the system expressed in time steps. This variable is used to setup the mass-like variables via the relations:


NHC_NRESPA


NHC_NS