{{TAGDEF|ELPH_ISMEAR|[integer]| | {{TAGDEF|ELPH_ISMEAR|-15 {{!}} -14 {{!}} -5 {{!}} -4 {{!}} -1 {{!}} 0 {{!}} [integer]>0 |0}} | ||
Description: | Description: Chooses the smearing method to determine the fermi level and chemical potential before an electron-phonon calculation. | ||
---- | ---- | ||
{{TAG|ELPH_ISMEAR}} is very similar to {{TAG|ISMEAR}}. | |||
The difference | The difference is that {{TAG|ELPH_ISMEAR}} is used to determine the chemical potential in the context of electron-phonon calculation. | ||
The Kohn-Sham states for which to calculate the chemical potential correspond to the <b>k</b>-point grid specified via the {{FILE|KPOINTS_ELPH}} file. | |||
The chemical potential is determined for the list of temperatures {{TAG|ELPH_SELFEN_TEMPS}} and carrier concentrations specified by | The chemical potential is determined for the list of temperatures {{TAG|ELPH_SELFEN_TEMPS}} and carrier concentrations specified by | ||
{{TAG|ELPH_SELFEN_CARRIER_DEN}} or {{TAG|ELPH_SELFEN_CARRIER_PER_CELL}}. Alternatively, one can specify the chemical potential and determine the carrier concentration using {{TAG|ELPH_SELFEN_MU}}. | {{TAG|ELPH_SELFEN_CARRIER_DEN}} or {{TAG|ELPH_SELFEN_CARRIER_PER_CELL}}. Alternatively, one can specify the chemical potential and determine the carrier concentration using {{TAG|ELPH_SELFEN_MU}}. | ||
== Tag options == | |||
;{{TAGO|ELPH_ISMEAR|1|op=>}} | |||
:Method of Methfessel-Paxton of order {{TAG|ELPH_ISMEAR}} (for details see {{TAG|ISMEAR}}) | |||
;{{TAGO|ELPH_ISMEAR|0}} | |||
:Gaussian smearing (for details see {{TAG|ISMEAR}}) | |||
;{{TAGO|ELPH_ISMEAR|-1}} | |||
:Fermi-Dirac smearing (for details see {{TAG|ISMEAR}}) | |||
;{{TAGO|ELPH_ISMEAR|-4}} | |||
:Tetrahedron method (zero temperature) (for details see {{TAG|ISMEAR}}) | |||
;{{TAGO|ELPH_ISMEAR|-5}} | |||
:Tetrahedron method (zero temperature) with Blöchl corrections (for details see {{TAG|ISMEAR}}) | |||
;{{TAGO|ELPH_ISMEAR|-14}} | |||
:Tetrahedron method (finite temperature) | |||
;{{TAGO|ELPH_ISMEAR|-15}} | |||
:Tetrahedron method (finite temperature) with Blöchl corrections | |||
==Related tags and articles== | |||
* {{TAG | ISMEAR}} | |||
* {{TAG | ELPH_SELFEN_MU}} | |||
* {{FILE | KPOINTS_ELPH}} | |||
[[Category:INCAR tag]][[Category:Electron-phonon_interactions]] |
Latest revision as of 15:06, 19 December 2024
ELPH_ISMEAR = -15 | -14 | -5 | -4 | -1 | 0 | [integer]>0
Default: ELPH_ISMEAR = 0
Description: Chooses the smearing method to determine the fermi level and chemical potential before an electron-phonon calculation.
ELPH_ISMEAR is very similar to ISMEAR. The difference is that ELPH_ISMEAR is used to determine the chemical potential in the context of electron-phonon calculation. The Kohn-Sham states for which to calculate the chemical potential correspond to the k-point grid specified via the KPOINTS_ELPH file.
The chemical potential is determined for the list of temperatures ELPH_SELFEN_TEMPS and carrier concentrations specified by ELPH_SELFEN_CARRIER_DEN or ELPH_SELFEN_CARRIER_PER_CELL. Alternatively, one can specify the chemical potential and determine the carrier concentration using ELPH_SELFEN_MU.
Tag options
ELPH_ISMEAR > 1
- Method of Methfessel-Paxton of order ELPH_ISMEAR (for details see ISMEAR)
ELPH_ISMEAR = 0
- Gaussian smearing (for details see ISMEAR)
ELPH_ISMEAR = -1
- Fermi-Dirac smearing (for details see ISMEAR)
ELPH_ISMEAR = -4
- Tetrahedron method (zero temperature) (for details see ISMEAR)
ELPH_ISMEAR = -5
- Tetrahedron method (zero temperature) with Blöchl corrections (for details see ISMEAR)
ELPH_ISMEAR = -14
- Tetrahedron method (finite temperature)
ELPH_ISMEAR = -15