(Created page with " == How to == === Anderson thermostat === * For a metadynamics run with Andersen thermostat, one has to: #Set the standard MD-related tags: {{TAG|IBRION}}=0, {{TAG|TEBEG}}, {{TAG|POTIM}}, and {{TAG|NSW}} #Set {{TAG|MDALGO}}=1 ({{TAG|MDALGO}}=11 in VASP 5.x), and choose an appropriate setting for {{TAG|ANDERSEN_PROB}} #Set the parameters {{TAG|HILLS_H}}, {{TAG|HILLS_W}}, and {{TAG|HILLS_BIN}} #Define collective variables in the {{FILE|ICONST}}-file, and set the <code>S...") |
No edit summary |
||
Line 1: | Line 1: | ||
=== Anderson thermostat === | === Anderson thermostat === | ||
Line 32: | Line 28: | ||
---- | ---- | ||
[[Category:Advanced molecular-dynamics sampling]][[Category: | [[Category:Advanced molecular-dynamics sampling]][[Category:Howto]] |
Latest revision as of 11:55, 16 October 2024
Anderson thermostat
- For a metadynamics run with Andersen thermostat, one has to:
- Set the standard MD-related tags: IBRION=0, TEBEG, POTIM, and NSW
- Set MDALGO=1 (MDALGO=11 in VASP 5.x), and choose an appropriate setting for ANDERSEN_PROB
- Set the parameters HILLS_H, HILLS_W, and HILLS_BIN
- Define collective variables in the ICONST-file, and set the
STATUS
parameter for the collective variables to 5 - If needed, define the bias potential in the PENALTYPOT-file
The actual time-dependent bias potential is written to the HILLSPOT-file, which is updated after adding a new Gaussian. At the beginning of the simulation, VASP attempts to read the initial bias potential from the PENALTYPOT-file. For the continuation of a metadynamics run, copy HILLSPOT to PENALTYPOT. The values of all collective variables for each MD step are listed in REPORT-file, check the lines after the string Metadynamics.
Nose-Hoover thermostat
- For a metadynamics run with Nose-Hoover thermostat, one has to:
- Set the standard MD-related tags: IBRION=0, TEBEG, POTIM, and NSW
- Set MDALGO=2 (MDALGO=21 in VASP 5.x), and choose an appropriate setting for SMASS
- Set the parameters HILLS_H, HILLS_W, and HILLS_BIN
- Define collective variables in the ICONST-file, and set the STATUS parameter for the collective variables to 5
- If needed, define the bias potential in the PENALTYPOT-file
The actual time-dependent bias potential is written to the HILLSPOT-file, which is updated after adding a new Gaussian. At the beginning of the simulation, VASP attempts to read the initial bias potential from the PENALTYPOT-file. For the continuation of a metadynamics run, copy HILLSPOT to PENALTYPOT. The values of all collective variables for each MD step are listed in REPORT-file, check the lines after the string Metadynamics.
References